Jorge Calderón-Parraa,, , Enrique Sánchez-Chicaa, Ángel Asensio-Vegasb, Ignacio Fernández-Lozanoc, Jorge Toquero-Ramosc, Víctor Castro-Urdac, Ana Royuela-Vicented, Antonio Ramos-Martíneza
a Unidad de Enfermedades Infecciosas, Servicio de Medicina Interna, Hospital Universitario Puerta de Hierro, Majadahonda, Madrid, España
b Servicio de Medicina Preventiva, Hospital Universitario Puerta de Hierro, Majadahonda, Madrid, España
c Servicio de Cardiología, Hospital Universitario Puerta de Hierro, Majadahonda, Madrid, España
d Unidad de Bioestadística, Instituto de Investigación Sanitaria, Hospital Universitario Puerta de Hierro, Majadahonda, Madrid, España
Recibido 30 abril 2018, Aceptado 30 agosto 2018
Resumen
Introducción y objetivos

El uso de dispositivos cardiacos implantables (DCI) se ha expandido en los últimos años. La infección relacionada con estos dispositivos es una de las principales complicaciones y se asocia con grandes morbilidad, mortalidad y costes. El objetivo del estudio es construir una puntuación predictiva del riesgo de infección del DCI.

Métodos

Se diseñó un estudio retrospectivo de casos y controles anidado. Tanto los casos como los controles pertenecían a una cohorte que incluía a todos los pacientes sometidos a un procedimiento relacionado con un DCI entre enero de 2009 y diciembre de 2015. Los casos se definieron como pacientes con infección, y se seleccionó aleatoriamente a 3 controles de la cohorte por cada caso incluido.

Resultados

Durante el periodo de estudio, se realizaron 2.323 procedimientos. Se identificaron en total 33 infecciones relacionadas con el DCI. Se seleccionó como controles a 99 pacientes. Se identificaron como factores de riesgo independientes el índice de Charlson (OR=1,33; IC95%, 1,07-1,67), la anticoagulación oral (OR=3,51; IC95%, 1,44-8,54), la revisión o el reemplazo de un dispositivo anterior (OR=2,75; IC95%, 1,12-6,71) y la presencia de más de 2 cables (OR=3,42; IC95%, 1,25-9,37). Se generó una escala de riesgo predictivo y se denominó CIED-AI (índice de Charlson, más de 2 cables/electrodos, revisión/reemplazo del dispositivo, anticoagulación oral, infección previa). Esta puntuación presentó un área bajo la curva receiver operating characteristic de 0,79 (IC95%, 0,71-0,88).

Conclusiones

La puntuación CIED-AI puede ayudar a identificar a los pacientes con mayor riesgo de infección que serían candidatos a medidas de prevención intensivas.

Abstract
Introduction and objectives

The use of cardiac implantable electronic devices (CIEDs) has expanded in recent years. Infection related to these devices constitutes one of the main complications and is associated with high morbidity, mortality, and financial cost. The aim of this study was to construct a predictive risk score of acquiring CIED infection.

Methods

We designed a retrospective, nested case-control study. Both cases and controls belonged to a cohort that included all patients who underwent a CIED-related procedure between January 2009 and December 2015. Cases were defined as patients with infection, and 3 infection-free controls were randomly selected from the cohort for each case included.

Results

During the study period, 2323 procedures were performed. A total of 33 CIED-related infections were identified. Ninety-nine patients were selected as controls. Independent risk factors were the Charlson index (OR, 1.33; 95%CI, 1.07-1.67), oral anticoagulation (OR, 3.51; 95%CI, 1.44-8.54), revision or replacement of a previous device (OR, 2.75; 95%CI, 1.12-6.71) and the presence of more than 2 leads (OR, 3.42; 95%CI, 1.25-9.37). A predictive risk score was generated and denominated CIED-AI (Charlson Index, more than 2 leads/Electrodes, Device revision/replacement, oral Anticoagulation, previous Infection). This score had an area under the receiver operating characteristic curve of 0.79 (95%CI, 0.71-0.88).

Conclusions

The CIED-AI score may help to identify patients at higher risk of infection, who could be candidates for intensive preventive measures.

Full English text available from: www.revespcardiol.org/en

Palabras clave
Dispositivo cardiaco implantable, Infección relacionada con DCI, Factor de riesgo, Calificación predictiva
Abreviaturas
DAI, DCI, ECN, MPP, TRC
Keywords
Cardiac implantable electronic device, CIED-related infection, Risk factor, Predictive score

Artículo

Puede acceder al texto completo de este artículo:

Socios de la Sociedad Española de Cardiología


Suscriptores de Revista Española de Cardiología

Si lo desea puede adquirir este artículo por 30.00 €

Comprar ahora
0300-8932/© 2018 Sociedad Española de Cardiología. Publicado por Elsevier España, S.L.U. Todos los derechos reservados.
Politica de cookies
x
Utilizamos cookies propias y de terceros para mejorar nuestros servicios y mostrarle publicidad relacionada con sus preferencias mediante el análisis de sus hábitos de navegación. Si continua navegando, consideramos que acepta su uso. Puede cambiar la configuración u obtener más información aquí.
Política de cookies
x
Utilizamos cookies propias y de terceros para mejorar nuestros servicios y mostrarle publicidad relacionada con sus preferencias mediante el análisis de sus hábitos de navegación. Si continua navegando, consideramos que acepta su uso. Puede cambiar la configuración u obtener más información aquí.